Propane Leak Test: it is known as a drop test, what does that mean? Well the 101 of it is this, I hookup a meter(manometer) that measures pressure, drop it to a certain point and leaving the propane tank turned off, wait a set amount of time and see if the pressure drops which implies a propane leak somewhere.
13.A.1 – LP Leak System Test | A | F | P | NI | NP |
13.A.2 – LP Leak/Drop Test | Pass | Fail | Not Tested | |
13.A.3 – LP Leak/Drop Pressure Drop | Yes | No | Not Tested | |
13.A.4 – LP Drop Test Start/End Time | Start Time: | End Time: |
Let’s do a test on the LP (aka propane) Detector), it is checked by either pushing the test button and/or using propane/butane spray at the sensor, they have a life limit as to when they should be replaced, usually 3-5 yrs, sometimes the detector will tell you on it when it needs to be replaced and other times not.
13.A.5 – LP Leak Detector | A | F | P | NI | NP |
13.A.6 – LP Detector Test Result | Pass | Fail | Not Tested | NP |
13.A.7 – LP Detector – Make/Model/Serial#/Date | Make: | Model: | Serial: | Date: |
13.A.8 – LP Detector – Test Method | Spraying LP | Push Button | Push Button and Spray LP | Not Tested |
CO (Carbon Monoxide) Detector Test, pushing button is the only way to tested it. It could be yours is both a CO and a Propane detector combo Unit.
13.A.9 – Carbon Monoxide Detector | A | F | P | NI | NP |
13.A.10 – Carbon Monoxide Detector Test Result | Pass | Fail | Not Tested | NP |
13.A.11 – Carbon Monoxide Detector – Make/Model/Serial#/Date | Make: | Model: | Serial: | Date: |
13.A.12 – Carbon Monoxide Detector – Test Method | Yes by push button | No by push button | Not Tested | NP |
Smoke Detector, same kind of test, push button
13.A.13 – Smoke Detector | A | F | P | NI | NP |
13.A.14 – Smoke Detector Test Result | Pass | Fail | Not Tested | NP |
13.A.15 – Smoke Detector Make/Model/Serial#/Date | Make: | Model: | Serial: | Date: |
13.A.16 – Smoke Detector Test Method | Yes by push button | No by push button | Not Tested | NP |
Fire Extinguisher, just checked to make sure the gauge indicates a charged state and the correct size based on whether the RV has a generator or not.
13.A.17 – Fire Extinguisher | A | F | P | NI | NP |
13.A.18 – Fire Extinguisher Size | TT w/o Generator 5BC | TT w/Generator 10BC | Motor Home/Generator 10BC | NP |
13.A.19 – Fire Extinguisher Secure in Bracket | Yes | No | NP |
13.A.20 – Fire Extinguisher Mounted within 24 inches of door | Yes | No | NP |
13.A.21 – Fire Extinguisher Gauge indicates charged state | Yes | No | NP |